      Hi there,

      I'm trying to make an user actor as a throughput node for "port" on note-on/off-watchers. I'd like to change the Data Type of  the "User Input" and "User Output" to the Data Type "Range", but it seems to be missing. Hope you can add it.

      Best regards,

      Thomas

      1 Reply Last reply Reply Quote 0
      • markM
        mark
        last edited by

        Dear @U-taka 

        If you simply add a User Input and connect it to the 'port' input, the User Input's port will "mutate" to a range input. There is no need to set the type manually.

        In case you don't know: many of Isadora's actor inputs or actor outputs offer the ability to "mutate" in this way. When the color of the input or output port (the little dot to which you connect the link) is green instead of blue, it is mutable, and will automatically change its data type when you connect a link to it.

        Best Wishes,
        Mark

        Media Artist & Creator of Isadora
        Macintosh SE-30, 32 Mb RAM, MacOS 7.6, Dual Floppy Drives